Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Assessment of Marginal Peri-implant Bone-Level Short-Length Implants Compared with Standard Implants Supporting Single Crowns in a Controlled Clinical Trial: 12-Month Follow-up
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 36 , Issue 6
November/December 2016

Pages 791–795


Assessment of Marginal Peri-implant Bone-Level Short-Length Implants Compared with Standard Implants Supporting Single Crowns in a Controlled Clinical Trial: 12-Month Follow-up

Gerardo Mendoza-Azpur, DDS, MSc/Miguel Lau, DDS/Erick Valdivia, DDS, MSc/Jorge Rojas, DDS/Henry Muñoz, DDS/Myron Nevins, DDS


PMID: 27740639
DOI: 10.11607/prd.3026

In oral rehabilitation, crown-to-root ratio is accepted as an indicator of bone loss, and this concept was transferred to implants. Recent studies have indicated that there is no significant difference between short and standard implants. The aim of this study was to compare marginal bone level alteration through radiographic evaluation and clinical parameters between short and standard implants supporting single crowns. This prospective clinical trial study included 82 systemically healthy, nonsmoking subjects. Patients were divided into two groups: one group for short dental implants measuring 5.5 or 7 mm, and one group for standard dental implants measuring 10 or 12 mm, in accordance with the individual needs of the patient. A clinical dental history was taken for each subject, including model casts, dental radiography, and cone beam computed tomography. A periapical analysis was also performed using ImageJ computer software to establish the initial bone measurement and periapical bone loss. A statistically significant difference was found in favor of the standard-length implants after 12 months, with greater gingival recession around the implant; however, bone loss in the short implants did not exceed 0.53 mm. The treatment with 5.5- to 7-mm-length implants is as reliable as treatment with 10- or 12-mm implants. Peri-implant bone loss is minimal, and therefore use of short implants can be recommended as treatment for the restoration of partially edentulous patients without the need for splinted crowns.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help